Rack Mount Units with GFCI Plugs Rack Mount PDUs
- Sheet
- P
- Listing
- ETL / UL 1363
- Origin
- Hamilton Twp, NJ
- Revised
- 2026-08-21
The Brooks rack mount units with GFCI plugs are 19 inch 1U power distribution units with a ground fault circuit interrupter on the end of the power cord, ETL listed to UL 1363. Outlets are built on the front, the rear, or both faces, and cord length and outlet count are specified per order.
Features
- Heavy duty black steel construction
- GFCI plug attached to the end of the power cord
- 15 amp or 20 amp
- Outlets on the front, rear, or both front and rear
- Circuit breaker and rocker switch on the front panel
- ETL certified to UL 1363
- Pilot light available in place of the rocker switch
- Twist-lock plug available in place of the standard plug
Configuration options
Every unit is built to order. The following attributes are configurable.
| Attribute | Options |
|---|---|
| Amperage | 15A or 20A |
| Outlet facing | Front, rear, or both front and rear |
| Outlet count | 6 or 8 on one face, or 8 rear with 6 front |
| Cord length | 6 ft or 15 ft |
| Rack size | 19 inch, 1U |
| Ground fault protection | GFCI plug on the end of the power cord |
| Switch | Rocker switch standard, pilot light available in its place |
- Option codes:
- Options: Duplex (D), Switch (S), Pilot Light (PL), Twist Lock (TL), No Breaker (NB), Isolated Ground (IG).
Standard configurations
All ratings 125 V, 60 Hz. The rating column gives the amperage.
| Model | Front outlets | Rear outlets | Total outlets | On/Off switch | Cord length | Rating (UL 1363) | Dimensions | Drawing |
|---|---|---|---|---|---|---|---|---|
| RM-120-GF | 6 | 0 | 6 | Yes | 6' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-130-GF | 6 | 0 | 6 | Yes | 15' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-220-GF | 0 | 6 | 6 | Yes | 6' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-230-GF | 0 | 6 | 6 | Yes | 15' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-240-GF | 0 | 8 | 8 | Yes | 6' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-250-GF | 0 | 8 | 8 | Yes | 15' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-280-GF | 6 | 8 | 14 | Yes | 6' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-290-GF | 6 | 8 | 14 | Yes | 15' | 15 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-720-GF | 6 | 0 | 6 | Yes | 6' | 20 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-730-GF | 6 | 0 | 6 | Yes | 15' | 20 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-740-GF | 0 | 6 | 6 | Yes | 6' | 20 Amps | 19" x 1 3/4" x 2 5/8" | |
| RM-750-GF | 0 | 6 | 6 | Yes | 15' | 20 Amps | 19" x 1 3/4" x 2 5/8" | |
| Model: We confirm these units carry a GF suffix. | ||||||||
Compliance and listings
- ETL listed to UL 1363
Compliance: BAA
Typical applications
The GFCI version is specified where a rack or cabinet needs ground fault protection at the plug rather than at the branch circuit: test benches, portable and field racks, and equipment installed where the supply receptacle is not itself GFCI protected.
Frequently asked questions
- How are these numbered against the standard rack mount units?
- The GFCI units carry a GF suffix, so RM-120-GF is the ground fault version of RM 120.
- Where is the GFCI fitted?
- On the end of the power cord, as a plug. The chassis is the same 19 inch 1U unit, and the front panel carries the circuit breaker and the rocker switch.
- Can outlets be on both the front and the rear?
- Yes. RM-280-GF and RM-290-GF are built with eight outlets on the rear and six on the front. Front only and rear only are also standard.
Request a quote on the Rack Mount Units with GFCI Plugs Rack Mount PDUs
Send your configuration.
- No minimum order: one unit to full production.
- A person reads every request and replies within two working days.
- ETL listed to UL 1363. Buy American Act compliant construction.
Products we manufacture carry a two-year warranty.
Last updated